High-Voltage Main Incoming Cabinet

High-Voltage Main Incoming Cabinet

Standard: IEC 62271-200
Rated voltage: 12kV / 24kV / 40.5kV
Rated current: 630A – 3150A
Power frequency withstand: 42kV/1min
Send Inquiry

What Is This Product? – It Is the First Door for Grid Power to Enter Your Factory

 

A High-Voltage Main Incoming Cabinet sits on the high voltage side of your substation.
It connects directly to the utility power lines.
Its job is to turn on, turn off, and protect the high voltage lines.
This product meets the IEC 62271-200 standard.
Rated voltages are 12kV, 24kV, or 40.5kV.
Rated current goes from 630A to 3150A.
Power frequency withstand voltage is 42kV for 1 minute.
Lightning impulse withstand voltage is 75kV.
The cabinet has a metal-clad, fully enclosed structure.
Each compartment is sealed separately to keep workers safe.
Big projects from China Railway, China Railway Construction, CCCC, and CSCEC use our High-Voltage Main Incoming Cabinet to connect to the grid.

product-800-800

 

FAQ

What is the "five-prevention" feature?

It prevents wrong opening or closing of the breaker, wrong closing of the grounding switch, and other unsafe actions.
This keeps operators safe.

 

What Materials and Processes Do We Use? – We Use Aluzinc Steel and a Vacuum Circuit Breaker

 

product-800-1067
product-800-1067

The outer shell uses 2mm thick aluzinc steel plate.
This material resists corrosion very well.
We double-bend and rivet it for high stiffness.
The main switch is a solid-sealed pole vacuum circuit breaker, like VS1 or VD4.
Mechanical life is 30,000 operations.
Electrical life is 10,000 operations.
Breaking capacity is between 31.5kA and 40kA.
The current transformers are epoxy resin cast and fully enclosed, with an accuracy class of 0.2S for metering.
The grounding switch has a fast closing mechanism and can close on a short circuit current.
All doors and panels have mechanical and electromagnetic locks.
We strictly follow the "five-prevention" sequence.
Our factory is 2,000 square meters and has ISO9001 certification.

 

Parameter

Value

Standard

IEC 62271-200

Rated voltage

12kV / 24kV / 40.5kV

Rated current

630A – 3150A

Power frequency withstand

42kV/1min

Lightning impulse withstand

75kV

Enclosure material

2mm aluzinc steel

Breaker type

VS1 or VD4 vacuum

Mechanical life

30,000 times

Breaking capacity

31.5kA – 40kA

CT accuracy

0.2S

 

What Are the Core Advantages? – Very High Power Continuity and Smart Protection

 

First, it is safe and smart to run.
The vacuum breaker has an integrated operating mechanism.
Opening time is ≤35ms, so the arc lasts very short.
We add a microcomputer protection relay, like REF615 or SEPAM.
It gives three-stage overcurrent, directional overcurrent, zero-sequence overcurrent, overload, and auto-reclosing.
Protection setting error is ≤3%.
It also supports IEC 61850 communication for digital substations.


Second, it has anti-condensation design.
We put a smart temperature and humidity controller with a heater inside.
This works well in humid areas like the south.


Third, operation is easy to see.
The front panel has a mimic bus diagram and status lights.
We provide full type test reports, plus seismic and internal arc test proof.
This High-Voltage Main Incoming Cabinet has utility-grade reliability.

product-704-797

 

FAQ

How many years has Anhui Nanxian Electric been in this field?

We have seven years of experience in power distribution.
We have served China Railway, China Railway Construction, CCCC, and CSCEC.
You can trust us.

 

Hot Tags: high-voltage main incoming cabinet, China high-voltage main incoming cabinet manufacturers, suppliers, Low Voltage Main Distribution Cabinet, Low Voltage Main Panel, LV Main Switchboard, LV MV Main Cabinet, Main Control Cabinet, Main Distribution Box

Send Inquiry

Send Inquiry