Main Distribution Cabinet
Max rated current: 6300A
Short time withstand current: 80kA/1s
Frame steel thickness: 2.0mm
What Is This Product? – It Is the Power Heart for a Factory or a Tall Building
A Main Distribution Cabinet takes the low voltage power from the transformer and sends it to other cabinets.
It sits in the main power room and can work with many transformers or generators.
This product meets the IEC 61439-2 standard.
Its highest current is 6300A.
The short time withstand current (Icw) is 80kA for 1 second.
So it can handle the shock from big machines.
The inside is split into separate rooms for the busbar, the function units, and the cables.
This makes work safer and maintenance easier.
We have served big customers like China Railway, China Railway Construction, CCCC, and CSCEC.
Their projects use this Main Distribution Cabinet as their power center.

FAQ
What Materials and Processes Do We Use? – We Use Strong Profiles and a Precision Busbar System


We build the frame with C-type or KB-type profiles.
The steel plate is 2.0mm thick and has double bends for high strength.
The surface first gets a nano-ceramic treatment, then an epoxy powder coating for double protection.
It passes a salt spray test for over 500 hours.
The main busbar is made of high-purity T2 electrolytic copper.
We design the current at 2.5A per square millimeter so the temperature rise stays under 70K.
All copper joints are tin-plated, and the contact resistance is ≤5μΩ.
The vertical busbar uses an "L" shape or a "sandwich" structure to lower inductance.
Protection level is IP40 or you can choose IP54.
We also add a pressure relief channel for internal arc faults, meeting IEC 61641.
Our factory is 2,000 square meters and has ISO9001 certification.
|
Parameter |
Value |
|
Standard |
IEC 61439-2 |
|
Max rated current |
6300A |
|
Short time withstand current |
80kA/1s |
|
Frame steel thickness |
2.0mm |
|
Salt spray resistance |
>500 hours |
|
Busbar material |
T2 electrolytic copper |
|
Temperature rise |
≤70K |
|
Protection rating |
IP40 or IP54 |
|
Arc fault protection |
IEC 61641 |
What Are the Core Advantages? – High Breaking Capacity Breakers with Smart Monitoring and Redundant Power
First, it is reliable and smart.
The main incoming switch uses a smart frame circuit breaker with a breaking capacity of 100kA.
It has LSIG full protection: long time delay, short time delay, instantaneous, and ground fault.
It also has zone selective interlocking.
So if a fault happens, only the smallest part of the system shuts down.
Other circuits keep working.
Second, smart monitoring is easy.
You can put up to 8 multi-function power meters inside the cabinet.
They connect through an RS485 port to a computer, so you can measure, read, and control remotely.
Third, you can add an automatic transfer switch (ATS).
We offer an ATS system that switches between main and backup power in ≤100ms.
Your critical loads never stop.
The cabinet size is made to your order.
Cable entry and exit can be top, bottom, or side.
We also leave 20% spare circuit space for future needs.
This product has CCC certification and type test reports.
It works great for data centers, hospitals, and large factories that need top-level power supply.


FAQ
Hot Tags: main distribution cabinet, China main distribution cabinet manufacturers, suppliers, HV Line Cabinet, Low Voltage Main Distribution Cabinet, LV Distribution Center, LV MV Main Cabinet, Main Distribution Cabinet, Primary HV Switchgear
You Might Also Like