High-Voltage Ring Main Unit
Standard: IEC 62271-200 & GB 3906
Rated voltage: 12kV – 24kV
Rated current: 630A
Short time withstand: 20kA/3s
Rated voltage: 12kV – 24kV
Rated current: 630A
Short time withstand: 20kA/3s
Send Inquiry
What Is This Product? – It Is a Compact High Voltage Cabinet for Ring or Dual Power Supply
A High-Voltage Ring Main Unit (RMU) is used in 12kV to 24kV distribution systems.
You often see it in city power grids, commercial buildings, residential areas, and solar or wind box substations.
It can work in a ring network or as a terminal distribution device.
This product meets IEC 62271-200 and GB 3906.
Rated current is 630A.
Short time withstand current is 20kA for 3 seconds.
The cabinet uses gas insulation (SF6) or solid insulation. It is small and maintenance-free.
We use a load break switch plus fuse combination, or we can add a vacuum breaker.
Residential power projects of China Railway and China Railway Construction use our High-Voltage Ring Main Unit.
You often see it in city power grids, commercial buildings, residential areas, and solar or wind box substations.
It can work in a ring network or as a terminal distribution device.
This product meets IEC 62271-200 and GB 3906.
Rated current is 630A.
Short time withstand current is 20kA for 3 seconds.
The cabinet uses gas insulation (SF6) or solid insulation. It is small and maintenance-free.
We use a load break switch plus fuse combination, or we can add a vacuum breaker.
Residential power projects of China Railway and China Railway Construction use our High-Voltage Ring Main Unit.

FAQ
What Materials and Processes Do We Use? – We Use a Stainless Steel Gas Tank or Solid Epoxy Insulation
For gas insulated RMU, we weld a sealed tank from 3mm stainless steel plate.
We fill it with SF6 gas at ≤0.04MPa. The yearly leakage rate is ≤0.1%.
For solid insulated RMU, we cast everything in epoxy resin. No gas, no pollution.
The main switch is a three-position load break switch: closed, open, and grounded.
Mechanical life is 5,000 operations.
The fuse protects the transformer and clears faults in ≤10ms.
The cable compartment has enough space and supports front or rear cable entry.
Protection rating: gas tank IP67, outer shell IP4X.
Our factory is 2,000 square meters with ISO9001 certification.
We fill it with SF6 gas at ≤0.04MPa. The yearly leakage rate is ≤0.1%.
For solid insulated RMU, we cast everything in epoxy resin. No gas, no pollution.
The main switch is a three-position load break switch: closed, open, and grounded.
Mechanical life is 5,000 operations.
The fuse protects the transformer and clears faults in ≤10ms.
The cable compartment has enough space and supports front or rear cable entry.
Protection rating: gas tank IP67, outer shell IP4X.
Our factory is 2,000 square meters with ISO9001 certification.

|
Parameter |
Value |
|
Standard |
IEC 62271-200 & GB 3906 |
|
Rated voltage |
12kV – 24kV |
|
Rated current |
630A |
|
Short time withstand |
20kA/3s |
|
Insulation type |
SF6 gas or solid epoxy |
|
Tank material |
3mm stainless steel |
|
Leakage rate |
≤0.1% per year |
|
Switch life |
5,000 operations |
|
Protection (tank) |
IP67 |
What Are the Core Advantages? – Small Size, No Maintenance, and Automation Ready
The advantages are compact size and high reliability.
Cabinet width is only 375 to 500mm, saving a lot of floor space.
Gas insulation works in any environment: coastal, high altitude, or polluted areas.
We can add a motor-operated mechanism and a DTU (distribution terminal unit) for remote indication, measurement, and control.
Inside, we put a voltage indicator, phase test holes, and a fault indicator.
This product has passed the state grid one- and two-device integration test.
We offer a 5-year warranty and lifetime technical support.
Cabinet width is only 375 to 500mm, saving a lot of floor space.
Gas insulation works in any environment: coastal, high altitude, or polluted areas.
We can add a motor-operated mechanism and a DTU (distribution terminal unit) for remote indication, measurement, and control.
Inside, we put a voltage indicator, phase test holes, and a fault indicator.
This product has passed the state grid one- and two-device integration test.
We offer a 5-year warranty and lifetime technical support.

FAQ
Hot Tags: high-voltage ring main unit, China high-voltage ring main unit manufacturers, suppliers, High Voltage Outgoing Cabinet, HV Disconnect Panel, HV Kilowatt Hour Box, HV Meter Enclosure, Ring Main Cabinet, Ring Main Switchgear